Features
• 8 on-board zone inputs (16 with zone
doubling) expandable to 48 zones via 4-wire
combus
• 4 partitions
• 96 user codes
• 32 access control doors
• 1024 events buffered
• 95 expansion modules
• 2 on-board PGMs (+2 optional PGMs
and 1 bell relay)
• PGM1 can be used as 2-wire smoke detector
input
• 1.7A switching power supply
• Supervised bell output, auxiliary
output and telephone line
• Connect modules up to 900m (3000ft)
using 18AWG or 300m (1000ft) using 22AWG
• Includes 28cm x 28cm x 7.6cm (11"
x 11" x 3") metal box |
| |
|
|
 |
|
Features
• 8 on-board zone inputs (16
with zone doubling) expandable to 96 zones
via 4-wire combus •
8 partitions •
999 user codes •
32 access control doors •
2048 events buffered •
127 expansion modules •
3 on-board PGMs •
PGM1 can be used as 2-wire smoke detector
input •
1.7A switching power supply •
Supervised bell output, auxiliary output and
telephone line •
Built-in real-time clock backup battery (no
DGP2-TM1 required) •
Adjustable communication speed (normal/fast)
for large installations •
Connect modules up to 900m (3000ft) using
18AWG or 300m (1000ft) using 22AWG •
Includes 28cm x 28cm x 7.6cm (11" x 11"
x 3") metal box |
| |
|
|
| System
Accessories and Software |
 |
|
Features
• Connects directly on main board
•
4 addressable zones (8 with ATZ zone doubling
feature) •
Set a different input speed for each zone
(up to 7.65 seconds) •
Supported by DigiplexNE (DGP-NE96) |
 |
|
Features
• Used to divide the bus into
two completely isolated outputs (one output
failure does not affect the other)
•
To be added when over 600m (2000ft) of single
or multiple bus wires are used
•
Each output port can provide communications
up to 900m (3000ft) |
 |
|
Features
• Connects directly on main board
•
Keeps time and date during a complete power
failure •
8-year battery life expectancy (battery included)
•
Not required with DigiplexNE (DGP-NE96) |
 |
|
Features
• Download or upload control
panel programming in less than 5 seconds
•
Connect directly to memory connector on the
control panel •
No need for a telephone line, PC or any other
peripheral device |
 |
|
Features
• Enables main board to communicate
with a PC at 8m (25ft) •
Connect from main board’s serial port
connector to PC’s serial port (DB-9)
•
38.4k baud communication (DigiplexNE) or 19.2k
baud communication (Digiplex) |
 |
|
Features
• Enables main board to communicate
with a PC at 300m (1000ft) •
Connect from main board’s serial port
connector to PC’s serial port (DB-9)
•
38.4k baud communication (DigiplexNE) or 19.2k
baud communication (Digiplex) |
| |
|
|
| Keypad
and Display Modules |
 |
|
Features
• View zones on up to 32 floor
plans •
View status of all zones on one screen with
zone grid (V1.3 or higher) •
Simple text- and icon-driven menus with step-by-step
guidance •
Alarm clock and special reminders •
15 tunes for use with door chiming, entry/exit
delay and more •
Supports 8 built-in languages in two Language
Sets (user selectable):
- LS1: English, Spanish, Czech, French, Hungarian,
Italian, Portuguese and Slovak
- LS2: English, Bulgarian, Czech, Polish,
Romanian, Russian and Swedish •
Smart search functions •
Copy and paste user programming •
Assign to one or more partitions •
Independently set chime zones •
3 one-touch panic alarms •
Adjustable backlight, contrast and volume
•
Upload/download labels with Memory Key or
with the Module Broadcast feature •
On-site upgradable firmware with Universal
In-Field Programmer •
Dimensions (with door closed): 11.5cm x 17cm
x 3cm (4.5" x 6.8" x 1.3")
•
6.5cm x 6.5cm (2.6" X 2.6") graphic
LCD with a resolution of 128 X 128 pixels
|
 |
|
Features
• 32-character LCD with programmable
labels (via Memory Key or Module Broadcast
feature) •
Available in English, Spanish, Czech, French,
German, Hebrew, Italian, Polish, Portuguese,
Russian, Swedish or Turkish •
Assign to one or more partitions •
1 addressable zone and 1 PGM output •
Independently set chime zones •
14 one-touch action buttons •
3 keypad-activated panic alarms •
Adjustable backlight, contrast and scroll
speed |
 |
|
Features
• 48-zone LED display (each LED
can be set to display any zone number from
1 to 96) •
4-partition LED display (each LED can be set
to display any partition from 1 to 8)
•
Assign to one or more partitions •
1 addressable zone and 1 PGM output •
Independently set chime zones •
14 one-touch action buttons •
3 keypad-activated panic alarms |
 |
|
Features
• LED display shows the status
of either partitions 1-8, zones 1-48, or zones
49-96 •
3-in-1 product (comes with three different
display labels) •
Mount as a stand-alone unit or over any LCD
or LED keypad module •
Stack up to three annunciators •
Assign to one or more partitions |
| |
|
|
| Motion
Detector Modules |
 |
|
Features
• Patented Digital Motion Detection
(no analogue circuitry) •
Digital Auto Pulse Signal Processing
•
Digital Shield algorithm software •
Metal shield maximizes protection from EMI
and RFI signals •
12m (40ft) X 12m (40ft) range with 110°
viewing angle |
 |
|
Features
• Digital Dual Opposed Detection
•
Interlock Sensor Geometry (ISG) •
Patented Digital Motion Detection (no analogue
circuitry) •
Digital Auto Pulse Signal Processing
•
Digital Shield algorithm software •
Metal shield maximizes protection from EMI
and RFI signals •
12m (40ft) X 12m (40ft) range with 110°
viewing angle |
 |
|
Features
• Dual optics (2 dual opposed
element sensors) •
Provides superior pet immunity using a patented
combination of advanced optics and digital
processing technologies •
Immune to pets weighing up to 40kg (90lbs)
•
Extremely reliable and false-alarm free
•
Patented Digital Motion Detection (no analogue
circuitry) •
Digital Auto Pulse Signal Processing
•
Digital Shield algorithm software •
Metal shield maximizes protection from EMI
and RFI signals •
10.5m (35ft) X 10.5m (35ft) range with 90°
viewing angle |
 |
|
Features
The Digigard DG85 combines a special
weatherproof design and the proven technology
of our Digigard High-Security Motion Detector
with Pet Immunity (DG75) to provide the same
reliable protection—outdoors. •
Impact and temperature resistant casing
•
Extremely reliable and false-alarm free
•
Dual Optical Filtering System •
UV protected lens •
Patented Animal Immunity (up to 40kg/90lbs)
•
Dual optics (2 dual opposed element sensors)
•
Digital Dual Opposed Detection •
Multi-level sensitivity adjustment •
Two operational modes (addressable for Digiplex
and DigiplexNE or conventional relay operation)
•
11m (35ft) X 11m (35ft); 90° viewing angle
|
| |
|
|
| Hardwired
and Wireless Zone Expansion Modules |
 |
|
Features
• 1 addressable zone •
Small size: 74mm x 20mm x 30.5mm (2.9"
x 0.8" x 1.2") |
 |
|
Features
• 1 addressable zone (2 with
ATZ zone doubling feature) •
Set a different input speed for each zone
(up to 255 minutes), which is ideal for temperature
monitoring applications |
 |
|
Features
• 4 addressable zones (8 with
ATZ zone doubling feature) •
Set a different input speed for each zone
(up to 255 minutes), which is ideal for temperature
monitoring applications •
Use zone input as an anti-tamper switch input
|
 |
|
Features
• 8 addressable zones (16 with
ATZ zone doubling feature) •
Set a different input speed for each zone
(up to 255 minutes), which is ideal for temperature
monitoring applications •
1 PGM output •
Use zone input as an anti-tamper switch input
|
| |
|
|
| Access
Control Modules |
 |
|
Features
• Connections for card reader,
REX, door contact and lock output •
Automatic unlocking schedule •
Door left open and door forced options
•
Door unlock and extended delay timers
•
Grant access via card and/or access code (supports
CR-R885-BL PosiPIN reader) •
Unlock door manually with button or PGM event
•
Built-in 1.5A switching power supply (supervised
only if used) •
Supports 26-bit Wiegand card readers
•
Includes 20cm x 25.5cm x 7.6cm (8" x
10" x 3") metal box •
Unlock Door On Fire Alarm option •
Safe Mode option (during a communication loss,
the access control door connected to the module
can grant access to up to 4 specified cards
|
 |
|
Features
• Indoor intallation only
•
Up to 10cm (4") read range with CR-R702-A
ISO PosiCard •
Two status LEDs (red and green) and beeper
•
Output formats: 26-bit Wiegand, 37-bit Wiegand
and custom output formats •
Screw terminals •
Covers single gang box •
Dimensions: 11cm H X 7.3cm W X 2cm D (2.8"
H X 4.5" W X 0.8" D) •
Operating temperature: +10ºC to +65ºC
(+50ºF to +149ºF) •
Material: UV resistant, ABS plastic •
Available in black or white |
 |
|
Features
• Extreme weather-resistant design
•
Up to 10cm (4”) read range with ISO
card •
Wiegand, ABA and custom output formats
•
Tricolor LED display •
Advanced SwiftRead Technology •
Elegant face light |
| |
|
|
| PGM
Expansion Modules |
 |
|
Features
• 1 fully programmable 5A relay
output •
Deactivate PGM after event or timer •
Pulse PGM output for fire alarms |
 |
|
Features
• 4 fully programmable 5A relay
outputs •
Deactivate PGM after event or timer •
Pulse PGM output for fire alarms |
| |
|
|
| Special
Accessory Modules |
 |
|
Features
•
Arm, disarm, control on-board PGM and
verify system status via telephone •
Clear and concise voice prompts
•
Available in Czech, English, French,
Greek, Italian, Portuguese, Spanish and Turkish
•
1 PGM output |
 |
|
Features
•
Automatically/manually print reports
of zones/system events via a printer and/or
PC •
Parallel and serial port connectors
•
Assign to any or all partitions
•
1 PGM output •
Available in English or Spanish |
 |
|
Features
•
1.7A switching power supply •
Fully supervised (AC, battery, low
battery and auxiliary limit) •
Selectable battery charge current (350mA/700mA)
•
1 PGM output •
Includes 20cm x 25.5cm x 7.6cm (8"
x 10" x 3") metal box |